SITRANS FUH1010 Interface Detection (Oil)
 SITRANS FUH1010 Interface Detection (Oil)
SITRANS FUH1010 Interface Detection (Oil)
Description
The SITRANS FUH1010 clamp-on non-intrusive ultrasonic interface detector is ideal for oil applications that require differentiation between various liquids in a pipeline and determination of liquid quality.
The interface detector is available in single and dual channel/path configurations. There are three enclosures to choose from: wall mount, wall mount explosionproof and compact explosionproof.
Application examples include interface detection, product identification and density indication.
Pair the SITRANS FUH1010 interface detector with the SITRANS F US Thickness Gauge to ensure precise flow measurement.
Detail
| Measuring range | ±12 m/s (±40 ft/s) bidirectional | 
| Nominal sizes | DN 6 to DN 9140 (0.25" to 360") | 
| Accuracy | ±0.05 of API number | 
| Repeatability | ±0.01% of API number | 
| Inputs | 4 digital, 4 analog, 2 temperature | 
| Outputs | 4 analog, 4 frequency, 2 status | 
| Communication | RS232, MODBUS | 
| Ambient temperature | -18 to 60 °C (0 to 140 °F) | 
| Medium temperature | -40 to 120 °C (-40 to 250 °F) | 
| Enclosure ratings | Wall mount: IP65 (NEMA 4X) Wall mount explosionproof: IP66 (NEMA 7) Compact explosionproof: IP65 (NEMA7) | 
| Approvals | INMETRO, CSA, FM, CE, ATEX, C-TICK | 
Benefits
- Allows direct replacement of intrusive densitometers with liquid density and API number outputs
- Maintains exceptional repeatability independent of changes in temperature, density or viscosity
- Eliminates straight run piping requirements
- Reduces capital cost by inferring density, alleviating need for additional equipment