SITRANS F M MAG 1100
SITRANS F M MAG 1100
Description
SITRANS F M MAG 1100 is a wafer design sensor in stainless steel with highly resistant liners and electrodes and is designed for the general industry environment. The flangeless wafer design meets all flange standards.
The SITRANS F M MAG 1100 is used in all industries where the corrosion-resistant stainless steel housing and the highly resistant liner and electrodes fit even the most extreme process media.
In order to have a complete flowmeter please combine it with one of the following MAG transmitters:
SITRANS F M MAG 5000: Cost efficient transmitter, accuracy of + 0.4 % of flow rate
SITRANS F M MAG 6000: Bus communication, batch function and accuracy of + 0.2 % of flow rate
SITRANS F M MAG 6000 I: Alu enclosure, Ex approvals, bus communication, batch function and accuracy of + 0.2 % of flow rate
Application examples: Process industry, Chemical industry, Water treatment
Detail
Meassuring range | 0 to 10 m/s |
Nominal Sizes | From DN 2 to DN 100 (1/12" to 4") |
Accuracy | 0.2 % ±1 mm/s 0.4 % ±1 mm/s (PFA) |
Operating Pressure | Max. 40 bar (Max. 580 psi) |
Ambient temperature | From -40 to 100 °C (-40 to 212 °F) |
Medium temperature | From -30 to 200 °C (-22 to 390 °F) |
Liners | Ceramics PFA |
Electrodes | Platinum Hastelloy |
Material | Stainless steel AISI 316L (1.4404) |
Approvals | ATEX - 2 GD Zone 1, FM Class 1 div 2 |
Benefits
- Compact wafer design meets EN 1092, DIN and ANSI flange standards
- Easy Plug & Play field changeability of transmitter
- Compact or remote mounting possible
- Highly resistant liner and electrodes that are suitable for most extreme process media
- Designed to allow patented MAG in-situ verification using the SENSORPROM fingerprint